Solutions
Industry Solutions

Industry Solutions

More
Solutions
Services

Leveraging our core and differentiated strengths, we provide you with high-quality, comprehensive technology services

More
Solutions
News Center

we provide you with high-quality, comprehensive technology services

More
Solutions
Why Choose Us

We provide professional optical product testing services (laser product safety testing and performance parameter testing, photobiological safety testing for non‑laser products), as well as energy efficiency testing services (EU ErP energy efficiency testing, US DOE energy efficiency testing, California CEC energy efficiency testing), among others.

More
Solutions
Contact Us

If you have requirements for laser products (laser product safety testing and laser performance parameter testing) and energy efficiency testing (EU ErP energy efficiency testing, US DOE energy efficiency, California CEC energy efficiency, UK energy efficiency testing), please feel free to email us at: admin@ctnt-cert.com

More
Industry News

Shenzhen Zhongwei Testing Technology Co.,Ltd.

Industry News

UV lamp IEC 62471-6 certification

2026-07-28 Industry News

Standard positioning and version

IEC 62471-6:2022 "Photobiological safety of lamps and lamp systems - Part 6: Ultraviolet lamp products" is a specialized standard published by the 

International Electrotechnical Commission (IEC), specifically designed for lamp products primarily emitting ultraviolet radiation, providing radiation 

safety assessment, risk grouping, and safety requirements. This standard was officially released in October 2022, with the corresponding EU version 

being EN IEC 62471-6:2023.


Scope of application determination

The standard is applicable to lamps and systems that primarily emit ultraviolet radiation (wavelength 180 nm to 400 nm). Typical products include 

UV LED lamps, low and medium pressure mercury lamps, excimer lamps, deuterium lamps, etc. The judgment condition is that the ultraviolet band 

(180 nm-400 nm) accounts for more than 50% of the total radiation power from 180 nm to 3000 nm. If the proportion of ultraviolet radiation is less 

than 50%, the basic standard IEC 62471 should be used for evaluation.

The standard clearly covers ultraviolet medical diagnostic and cosmetic equipment, but does not include general lighting fixtures, infrared heating 

lamps, fluorescent lamps for sunbathing (covered by IEC 60335-2-27 and IEC 61228), and ultraviolet therapeutic medical equipment (covered by 

IEC 60601-2-57).


Risk grouping system

The standard divides ultraviolet lamp products into four risk levels based on the degree of light radiation hazard:

RG-0 (Exemption Group): No photobiohazard under normal use conditions

RG-1 (low-risk group): Safe under normal behavior, no special protective requirements

RG-2 (medium risk group): relies on natural avoidance reactions of humans (such as glare discomfort) to ensure safety

RG-3 (high-risk group): Even short-term exposure can pose hazards and requires strict engineering control


Time weighted average (TWA) exposure concept

Due to the photobiological effects of ultraviolet radiation being based on the total cumulative dose, the standard adopts the concept of "time 

weighted average" exposure. The evaluation distance is determined based on the actual application scenario and expected exposure duration, 

rather than a fixed distance. For example, the evaluation distance for household ultraviolet cleaning lamps is usually 0.5 meters, professional 

ultraviolet air disinfection equipment can reach 1 meter, and upper room ultraviolet (GUV) lamps may be 2-3 meters. This is significantly different 

from the more general evaluation method in the basic standard IEC 62471.


Core testing content

The test needs to be conducted in the maximum output power mode of the lamp, using a spectral radiometer and radiometer to measure the 

radiation intensity in the 180nm – 400nm band, with a focus on evaluating the UV-B and UV-C bands. The test needs to simulate the worst-case 

exposure level, compare the measured effective irradiance with the risk grouping limit specified in the standard, and determine the corresponding 

risk level. For the 180nm-200 nm wavelength range, due to strong oxygen absorption, testing is only conducted under specific conditions.


Engineering control requirements

For RG-2 and RG-3 grade ultraviolet lamp products, the standard proposes mandatory engineering safety measures, including:

Protective casing or shielding device

Human proximity sensor

UV beam direction control

Alignment requirements for ultraviolet lamps in the upper room

Delay start timer

Exposure time control or automatic shutdown function

Interlocking protection device for detachable baffle


Label and User Information Requirements

Manufacturers must provide complete safety information in product labels and user manuals, including:

Risk level identification (RG-0 to RG-3)

Warning symbols and language for ultraviolet radiation

Safe use distance and maximum allowable exposure time

Explanation of Risk Reduction Measures

Limited usage conditions

Maintenance and service information

Applicable scenario description


Overview of Certification Process

The complete IEC 62471-6 certification usually includes the following steps: submitting product technical information (specifications, circuit diagrams, 

instructions for use, etc.) → preparing representative samples (2-3 finished lamps) → conducting spectral scanning and irradiance measurement in the 

laboratory → calculating hazard values according to weighting functions and comparing them with limit values → determining risk levels → issuing test

 reports and compliance certificates. The testing cycle for UV products is usually 10-15 working days.


Relationship with other standards

IEC 62471-6 is the sixth part of the IEC 62471 series of standards, used in parallel with the basic standard IEC 62471:2006. If the product involves 

electrical safety, EMC and other requirements, comprehensive certification must be conducted in conjunction with relevant standards such as 

IEC 60335 and IEC 60601. In the EU market, this standard is usually used as the technical basis for photobiological safety assessment in CE certification.